    They use evaporative cooling systems. The water absorbs the heat, turns into water vapor, and is vented into the air. In theory I assume it could be collected, but that would require a lot more post processing to cool it back down or compress it to get back to liquid for.

    • Brkdncr@lemmy.world
      link
      fedilink
      English
      arrow-up
      2
      arrow-down
      1
      ·
      1 day ago

      Most high rises have cooling systems. They run ambient temp water to all of the floors, and tenant hvac units cool their server rooms by pumping heat into that water.

      It then goes through the loop and gets cooled back down to ambient with large radiator systems outside.

      It’s closed loop.

      There’s no reason this can’t be applied to datacenters.

      • BassTurd@lemmy.world
        link
        fedilink
        English
        arrow-up
        1
        ·
        15 hours ago

        I’d imagine DCs are doing it the cheapest way they can. But I think comparing the high rises to a DC doesn’t really work just due to the scale difference and the amount of heat needing removed. I’m sure there’s a way that it could be made something of a closed loop for DCs, but I’m guessing it would be a bit different if a process compared to high rises. I wouldn’t be surprised if a DC removed as much heat as a year of every high rise in NYC in a day or less…

        • Brkdncr@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          ·
          15 hours ago

          Agreed, but i would think it’s mostly an upfront cost. Datacenters have massive footprints, the roofs could be covered with heat exchangers, also covered with solar panels. It just takes some regulation to encourage it.

          If you want to get really into it, you could figure out a way to reclaim all that heat energy.

          • BassTurd@lemmy.world
            link
            fedilink
            English
            arrow-up
            1
            ·
            15 hours ago

            If like to see a true engineer mock or what it would entail. I think it would require a dedicated facility to pull it off given just how much heat needs removed and the volume of water used. The problem is there is an insane amount of heat energy from these DCs. It has to go somewhere, and water is a very good medium for that. That heat still has to go somewhere, so removing it from the water is much harder. If you had a huge setup of heat exchangers, they could probably do it with enough time and space, but time isn’t an option, because they run continuously. It would probably end up being just a huge holding tank that lets the hot water cool over time.

            I don’t think anything like solar is going to help. It would be good environmentally to offset some of their power consumption, but I think it would be negligible in their overall power draw and wouldn’t have any effect on their cooling. It’s not like they are cooling airspace, which they also are, but it’s the components themselves.